Durable Stud Channel

Durable Stud Channel
In suspended ceiling assemblies, Ceiling Studs are technically designated as Furring Channels (commonly termed Hat Channels owing to their geometry) or Cross Tees within exposed grid layouts. Installed perpendicular to the main runners, these horizontal framing members provide the primary substrate for direct drywall screw-attachment or perimeter support for lay-in ceiling tiles.
Key Component Layers
Intermediate Channel (Main Runner)
The primary load-bearing channel suspended from the soffit via hanger wires.
Furring Channel Clip
A heavy-duty wire locking clip used to securely mechanically fasten the ceiling stud (furring channel) to the intermediate channel above without allowing lateral slippage.
Ceiling Stud (Furring/Hat Channel)
A roll-formed, hat-shaped galvanized steel section (typically 35mm wide face x 22mm deep x 0.50mm thick) with knurled faces to prevent screws from slipping during installation.
Drywall Fasteners
Bugle-head drywall screws (Type S for metal framing) driven through the plasterboard into the face of the ceiling stud.
Sizes Available
Parameter Available Specification
Length 3660 MM & 2440 MM
Thickness 0.50 MM
Standard Technical Specifications
Element Professional Specification Requirement
Furring Stud Spacing 400mm center-to-center for 12.5mm boards; 600mm max for thicker or multi-layer boards.
Material / Gauge Minimum 0.50mm (26-gauge) galvanized steel matching Grade G300 / Z180 standards.
Screw Spacing Maximum 200mm intervals along the length of each ceiling stud.
Edge Clearance The first and last ceiling stud must sit within 150mm of the perimeter wall track.
Overlap / Splicing Minimum 200mm nest lap, securely bound with two wafer-head framing screws on both flanges.