Floor-Ceiling Assembly (technically called a Horizontal Assembly) refers to the complete multi-layered sandwich that separates two vertical stories. It functions simultaneously as the load-bearing floor for the upper room and the acoustic/fire-protected ceiling for the lower room.
Key Component Layers (Top to Bottom)
A professional construction section divides the assembly into three distinct zones: the upper floor finish, the structural core, and the suspended ceiling plenum.
1. Upper Floor Finishes
The visible floor layer (e.g., engineered wood, tile, luxury vinyl tile) laid over a specialized acoustic underlayment mat (such as a 6mm rubber or cork mat) to deaden structural footstep noise.
2. Acoustic Topping / Subfloor
A 25mm to 38mm thick lightweight gypsum concrete pour (Gypcrete) laid over a 19mm structural plywood subfloor, or directly onto a raw concrete slab. This provides bulk mass to stop airborne noise.
3. Structural Elements
The load-bearing core, consisting of either a reinforced concrete slab (150mm–200mm), structural steel bar joists, or engineered wooden I-joists.
4. The MEP Plenum (The Gap)
The hollow cavity or "drop zone" housing mechanical ducts, electrical conduits, plumbing pipes, and sound-attenuation mineral wool batts.
5. Ceiling Suspension & Board
Metal resilient channels (RC-1) or suspension grids mounted to the underside of the structural framing, carrying Type X fire-rated plasterboard.
Sizes Available
| Parameter | Available Specification |
|---|---|
| Length | 3660 MM & 2440 MM |
| Thickness | 0.50 MM |
Standard Technical & Code Specifications
| Engineering Metric | Standard Building Code Requirement | Purpose |
|---|---|---|
| STC Rating (Acoustic) | Minimum STC 50 (Recommended STC 55–60 for luxury spaces). | Blocks airborne sound (talking, music) from traveling between floors. |
| IIC Rating (Impact) | Minimum IIC 50 (Recommended IIC 55+ with carpets/mats). | Deadens impact sound (footsteps, dropping objects) from moving downward. |
| Fire Resistance Rating | 1-Hour to 2-Hour FRR (Per UL Design L514, L589, or similar). | Slows down structural collapse and prevents fire from spreading vertically. |
| Clear Height (NBC India) | Minimum 2.75 meters (9 feet) from finished floor to finished ceiling. | Ensures structural and habitability comfort in living spaces. |